Wednesday, November 25, 2026

Oh, What Fun!

     "I need a network cable run from [a large wiring chase in the front room] to the old telephone connections in the basement at the North Campus."

     It was an email from my boss and of course, I replied "Sure!"  There were two easy(ish) possibilities, plus a brute-force path, but each and every one of them was going to require climbing into a wiring chase -- a fancy name for an enclosed space for signal wiring where heating/cooling air does not flow* -- that is knew was going to be inconvenient when we planned it in 1996, turned out to be more so once built, and has only become more difficult to get into and out of as I have aged.  Unless my eventual replacement is both slender and agile, I will probably be the last person to climb in there, and I have been the only person since it was finished.

     The new gadget in the basement does some stuff I will not specify; at the far end, it talks to a normal managed network switch that's inside our "firewall" and you couldn't get at it even if you knew its address.

     Once onsite, I looked over the situation.  The fattest conduit that goes close to where I need to get at each end is stuff full, mostly of dead, legacy cables that I'm going to need help wrangling.  Next smallest has plenty of room in it, and even a nice, woven-cloth "pull tape," twice the length of the conduit run, secured at each end.  You can almost tow a car with that stuff!  There's an ugly set of back-to-back 90-degree LBs near one end, to accommodate a jog that gets it to where it needs to go, the result of hooking up two unused and originally unrelated conduit runs.  But LBs are those long oval-shaped widgets that have a removable plate on one side, so I don't have to haul the cable through by main force; it only requires patience.

     Step one, unhank the pull tape from where it is stashed at the basement end, work it up through the LBs, and lay out a big loop on the floor.

     Step two, get a six-foot stepladder and climb into the wiring chase.  It's a boxed-in area above five 19" equipment racks that are more than six feet tall.  There are three hinged metal doors a little less than a yard square above them at the back, with the tops of those doors even with the suspended ceiling, but only one (1) door isn't partially blocked by conduit on the inside.  (This is the result of poor communication between us, our architect, the carpenters and the electricians in 1996: we built the room before we had the equipment racks or knew where the conduit as going to go.)
    To get in to the chase, I have to put a six-foot ladder in line with the opening, climb up, open the door, climb in to past waist level, rotate myself so I can sit on the floor of the chase and pull my legs in.  At that point, I can stand up; the actual ceiling is fourteen feet above the floor and the base of the chase is about seven feet up.  But wait!  There's a yard-high bar joist running through the long axis of the space, lots of conduit going here and there, and a few bits of unistrut to support the conduit.  So I stand up carefully.  On the far wall, a series of square lops support my kind of wiring: old audio and video, never digital signals, various kinds of control wiring and network cabling, all grouped by kind and type.  There's a trouble light on a retracting spool next to the hatch, which I turned on and stuck into the chase before climbing in.
     At one end of the wiring chase, above the last rack in the row, there's an opening into a long crawlway that traverses the half the width of the building.  It's at least fifteen feet long, a yard high, and four feet wide, with the bar joist running just a little off center down the entire length of it.  The "floor" of it is a row of conduits supported by unistrut.  This is good, because it's (unofficially) load-bearing, and I have made that crawl many times; but it's bad, because there's not even room enough to turn around and I have to crawl on an unyielding "corduroy road" of variously-sized conduit and the clamps that hold it to the unistrut.  (That's the brute-force path; there are stubs of conduit that run through the fire-rated wall at the far end of the crawlway and an open path for my plenum-rated cable on the other side, but it requires very tall ladders and it's a lot of work.)  No need for that today -- the conduit I want is one of the row that ends at the opening to the crawlway.  I grab the end of the pull tape, leaving it tied to the conduit, and carefully pull the whole free length through, feeding it out the hatch and down to the floor.  Since it's also still tied at the far end, when it stops, it's done.
     I can now climb back out of the space, a Limbo move that requires sitting on the floor of the chase, sticking my legs out the hatch, finding the ladder and eeling out face up until I can put my weight on the ladder, rotate face down, and back out while descending the ladder.

     Step three, use electrical tape to fasten the network cable to the pull tape, at the mark that ensures it will be all the way through when the tape is pulled tight.  Then I go to the far end, pull gently until it stops, go back to the racks and climb into the chase, where I can help the end of the cable into the conduit (it always hangs up), climb back out and pull the cable and tape all the way through to the little jog and the LBs.  Once the tape is tight, I lay it out of my way, untape the cable, and pull through enough extra to reach the final destination.  And because I hate tripping over things, I coil up the loop of pull tape, hank it, and stash it out of the way.

     Step four is just fiddly, working the network cable through the LBs and down onto the basement.  Down there, it's smooth sailing, just simple open loops to carry the cable to the new equipment.  I leave plenty of extra, because I'm not doing this all over again today.

     Step five is back at the racks.  I unspool sufficient cable to get to the network switch inside one of the racks, plus ten feet for oops, cut it and tape over the end.  (Why?  Well, I'll be running it onto a rack full of stuff, including live outlet strips down one side.  What could go wrong?  Let's not find out!)  Then I climb back into the wiring chase, carefully route the cable, climbing over and under conduit until I can feed it down through a stub of two-inch conduit into the right rack.  Back out, taking the trouble light with me, and then I can move the ladder out of the way, open the back door of the rack, find my cable, and route it over to the switch.

     Step six, terminate the cable.  Either you have installed RJ-45s or you haven't.  It's kind of fiddly; all the wires have to be untwisted, smoothed out and arranged in the correct order, before getting trimmed and fed into the modular connector and strain relief, which gets crimped on with a specialized tool.  Modern plenum-rated Cat. 6 network cable (all we buy these days) has a tough outer jacket that has to be stripped away first, and we cheat with "EZ-RJ" connectors† that let you run the wires out the front of the connector and check they're in the correct order before crunching them down and trimming the ends with the tool.  Having done that, I go repeat the process at the basement end, pick up the wire scraps, other trash and tools, make sure covers are back on and so forth.  It's all done until it comes time to test it, later.

     Every time I get into and out of the cable chase these days, I wonder if that will be the last time.  We do more and more with fewer and fewer wires and cables, and I am not getting any more limber.  As I write this on the following morning, I can feel my back aching a little.  It wasn't too much -- but it was closer than I'd like.
__________________
* Why is that, and who cares?  Remember, this is a lot of wiring, or it could be, and the climate-control system is moving the air you and I breathe.  We call any place indoors where that air moves a "plenum."  If there's a fire -- maybe my wiring went wrong, or you threw a cigarette into the trash, or a mouse ate lead azide and exploded -- the wire and especially the insulation on it, needs to not burn especially easily, and to not produce toxic smoke if it does.  This, however, gets expensive, so we pay the big bucks for "plenum rated" wire in people spaces, and use older, cheaper, non-plenum-rated wire and cable inside conduits and wiring chases and so on.
 
† People -- techs, anyway -- either hate these or love them.  Because of the way they are made, they can go very wrong, and a dull trimming blade can become a big problem.  Correctly assembling an RJ-45 requires practice; you need to do a lot of them wrong before you start consistently getting them right.  This kind of connector helps with the most common causes of incorrect assembly, but introduces new points of failure if you're not careful. 